Project Summary

What was needed?

The roof covering at Tekira Shopping Mall in Tekirdağ had reached the end of its service life. Considering the weakening waterproofing, the risk of leaks inside and the maintenance costs, the decision was made to renew the roof with a durable, UV-resistant TPO membrane system. Karatay took on the roof renewal turnkey, from survey to handover.

The Situation

Operational realities

Beneath the roof were shops, common areas and constant visitor traffic, so not a single drop of water could get inside during the works. The air-conditioning units, smoke vents, rooflights and rainwater outlets on the roof had to keep working, and the weather made planning even harder.

Our Approach

How we managed it

Before work began, the whole roof was inspected on site: the condition of the existing covering, insulation and deck was recorded and areas of moisture and damage were marked. A mechanically fixed TPO membrane system with hot-air welded seams was chosen, and separate details were prepared for critical points such as parapets, rooflights, equipment supports and outlets.

Process Management

Site coordination

The roof was divided into sections, each of which could be closed within a day.
At the end of every shift, the opened section was made temporarily watertight.
Weather forecasts were followed daily and no stripping was done on days with a risk of rain.
The air-conditioning and smoke extraction systems on the roof were kept running in coordination with the operations team.
Lifelines and edge protection were installed for work at height, and materials were delivered at night.
Outcome

Delivered without interrupting operations

The roof renewal was completed while the mall was open.

No water leaked inside during the works.

All seams and details were checked and handed over after watertightness tests.

The new TPO covering gives the mall a long-lasting, low-maintenance roof.